Product Description

QS-P220 Air Pressure Switch for Compressors, Pumps and Hydraulics: Long-Life Diaphragm, Factory Set 0.1–50 Bar

Xi'an Qintai Automotive Emission Technology Co., Ltd. builds the QS-P220. It is a diaphragm-type air pressure switch, and it ships preset from the factory. Compressors carry it. Pumps and hydraulic systems use it as well. Setpoints stretch from 0.1 to 50 bar, and the factory sets each one to your figure. A long service life is what the diaphragm was designed for. Back in 2001 the company was founded, and it holds national high-tech enterprise status today. Sensor cores and thick-film parts get made in-house. Need a particular setpoint or layout? OEM and ODM support handles that. Send over your pressure range. Add the application and the quantity. Our team then confirms the right option for you.

What the QS-P220 air pressure switch does

This product reads changes in air or gas pressure. When the reading hits a preset setpoint, out goes an electrical signal. That signal, on the QS-P220, links a pneumatic system to an electrical control circuit.

Most jobs are simple ones. The switch starts a compressor motor, then stops it again. It also reports pressure changes coming from pumps. Hydraulic equipment and pneumatic equipment use it the same way.

How the Switch Works

On a compressor, the switch takes charge of the motor. Tank pressure reaching the set value makes the diaphragm break the circuit. The motor stops. Air gets used, pressure drops, the contacts close once more, and the motor starts again. This this product cycle repeats the whole time the compressor runs.

Your system decides how the unit gets wired, how the contacts are set up, and whether an unloader or relief valve is part of the layout. Look all of this over before you install it.

Product Specifications

ItemSpecification
ModelQS-P220
DiaphragmLong-life
Factory set range0.1–50 bar

The supplied specification data does not list other technical details. These include electrical rating, contact type, port thread, media compatibility, operating temperature, and ingress protection. Get in touch with us to confirm them before you order.

Key Features

  • Long-life diaphragm: built to handle pressure cycling again and again.
  • Factory-set range: pick a setpoint anywhere from 0.1 to 50 bar.
  • OEM and ODM support: you can send requests based on your own specifications, application, and project needs.

Applications

The QS-P220 air pressure switch is listed for the following uses:

  • Compressors and pumps
  • Hydraulics
  • Pneumatics
  • Engine controls
  • Construction equipment
  • Agricultural equipment

Talk to us before you pick a setpoint. We will confirm the media, the pressure, and the electrical requirements with you.

def urea pump warehouse

Basic Bench Test

Treat this as a general procedure. Wiring and terminals change from model to model. Go by the wiring diagram that came with your own unit first. Bench testing This product works like this:

  • Kill the power first. Then bleed the pressure out of the system.
  • The housing design lets you take the cover off.
  • Tag the switch leads, then pull them off the terminal block. No wires get cut. Leave the incoming power wiring as it is.
  • Connect a controlled pressure source to the switch port.
  • The switch leads you just took off are where the ohmmeter leads go now.
  • Raise the pressure a little at a time. Then check the reading at the setpoint. It has to flip between open and closed. Once closed, the value should sit near zero ohms.
  • An adjustment screw ships with some models. Turn it only the way the instructions tell you, then run the test again.

Manufacturer, Testing and Quality

Xi'an Qintai Automotive Emission Technology Co., Ltd. started in 2001 and holds national high-tech enterprise status. The payroll is 420 people. Among them are 86 R&D technicians, and the company has filed for 58 invention patents. Sensor cores and thick-film printing both come out of its own plant. Across the whole company, pressure sensor output can reach 2 million units per year. That number does not apply to the QS-P220 alone. Buyers in more than 60 countries and regions use the products.

A 400 m² testing center is run by the company. It holds over 100 testing and inspection devices. More than 20 of those are specialized units. Microscopic inspection and dimensional measurement are part of the checks. Physical and chemical properties get tested too. So do environmental, mechanical and electrical loads. ISO 9001 and IATF 16949 back the quality management system. Certification documents differ from product to product. Please ask which ones cover your QS-P220 order.

def urea pump certificate

Qintai sensor factory production line

Packaging and Delivery

Storage follows standard inventory procedures with traceability. For packaging, protective foam is one option. Anti-static materials are available as well. So are reinforced cartons. Customized packaging can be arranged too.

Staff check barcodes before shipment. Quantities get verified at the same time, along with appearance and packaging integrity. Production of air pressure switch usually takes 1–2 weeks. Some in-stock items ship within one week. Air freight, sea freight or express delivery are all available.

def urea pump Qintai partners

def urea pump exhibition

def urea pump Package

FAQ

Q: What setpoint range is available?

A: Any point between 0.1 and 50 bar can be covered by the factory setting on the QS-P220. Just tell us the setpoint you need in your inquiry.

Q: Can the QS-P220 be customized?

A: Yes. OEM and ODM work is available. It starts with product design and ends with mass production. Your specs, application and project needs decide how we do it.

Q: How fast can it ship?

A: Production usually takes 1–2 weeks. Selected in-stock items ship within one week. Please confirm lead time for your quantity.

Q: Can it handle combustible gases?

A: Our current spec sheet does not cover use with combustible gases. Send us your gas type and how the system runs. We will check it for you before you place an order.

Q: The switch won't reset, or it trips at the wrong pressure. What should I check?

A: Check the sensing port for debris. The setpoint needs to sit far enough from normal pressure swings in the system. After that, look at the wiring. If the problem remains, send us the details of your application.