ATEX Pressure transmitter

QS-P202A
• Inflammable and explosive media and environment
• ATEX II 2G IIC T6, ATEX II 1G IIC T6,
• ATEX II 3G IIA T3,
• Certain stock for shortening delivery time
• High accuracy measuring
• compact dimension design
• pulse-snubber against cavitations and liquid hammer
Product Description

QS-P202A ATEX Pressure Transmitter for Explosive Environments: Compact, High-Accuracy Hazardous Area Sensing

Flammable gases and vapors call for sensing hardware that fits the hazardous zone around them. Xi'an Qintai Automotive Emission Technology Co., Ltd. makes the QS-P202A ATEX Pressure transmitter, and it is built for flammable and explosive media and environments. Three ATEX markings appear on it: II 2G IIC T6, II 1G IIC T6, II 3G IIA T3. Compare those with your own zone classification and gas group. Tight spaces are no problem either, thanks to the compact body. On pumped lines, a pulse snubber guards against cavitation and liquid hammer.

Key Features

What matters about this this product on hazardous-area projects:

  • Three ATEX markings (II 2G IIC T6, II 1G IIC T6, II 3G IIA T3) cover a range of gas groups and temperature classes
  • Compact body for limited installation space
  • Pulse snubber against cavitation and liquid hammer
  • Selected in-stock items for shorter delivery

Cavitation and liquid hammer cause pressure spikes in pumped lines, which is where the pulse snubber is most relevant.

Product Specifications

ParameterDetails
ModelQS-P202A
Media and environmentInflammable and explosive media and environments
ATEX marking 1II 2G IIC T6
ATEX marking 2II 1G IIC T6
ATEX marking 3II 3G IIA T3
Surge protectionPulse snubber against cavitation and liquid hammer

Several details are missing from the specification data we have. Pressure range is not there. Neither are output signal, thread, cable, accuracy figures, housing material, and ingress protection. Tell us what your project needs. Our engineers will then confirm which options fit.

How to Read the ATEX Markings

EU rules cover equipment built for places where an explosive atmosphere can form. ATEX assessment follows those rules. Directive 94/9/EC came in on 23 March 1994. Directive 2014/34/EU has since taken its place. Here is what each marking on the QS-P202A means:

  • II: equipment group for surface (non-mining) industries
  • 1G, 2G, 3G: equipment category for gas atmospheres. Zone 0 calls for category 1. Category 2 covers Zone 1. Zone 2 is where category 3 applies
  • IIC, IIA: gas group
  • T6, T3: temperature class. Top surface temperatures here reach 85 °C and 200 °C

Take each code and set it against the zone classification of your site. The temperature class needs a check too, against the ignition temperature of your medium. Three markings appear in the list. Please confirm which one fits the version you order.

Protection Methods

Two protection principles usually apply to hazardous-area transmitters. In a flameproof design (Ex d), ignition sources stay inside a strong housing. Intrinsic safety (Ex i) caps current and voltage. Energy then stays under the ignition level, even when a fault occurs.

The data we have doesn't say which method fits the QS-P202A. Go with intrinsic safety on This product and you'll need an intrinsically safe isolation barrier to pair with it. Talk to our team before you order. Confirm the protection method with them, and check the housing and the ingress protection as well.

Applications

Gas atmospheres are what the markings listed for the QS-P202A cover. That's why the examples below stick to flammable gases and vapors. Before you pick a model, check your zone classification. The medium needs a look too. This ATEX Pressure transmitter could work for:

  • Oil and gas: exploration and drilling, plus refining and storage
  • Chemical and petrochemical: making, blending, and holding
  • Pharmaceutical: work that uses flammable substances
  • Wastewater treatment: areas where methane may accumulate

The pulse snubber is useful in pumped lines where liquid hammer occurs.

def urea pump warehouse

About Xi'an Qintai and Quality Control

Xi'an Qintai Automotive Emission Technology Co., Ltd. has operated since 2001 and holds 58 invention patent applications. Its team of 420 people includes 86 R&D technicians. Sensor cores and thick-film elements are produced in-house on dedicated lines, and two sensor production lines support an annual capacity of 2 million pressure sensors. Buyers in more than 60 countries and regions source from Qintai.

The testing center covers 400 m². Inside it there are over 100 testing and inspection devices, and more than 20 of them are specialized instruments. Checks range from microscopic inspection to dimensional measurement. Physical and chemical properties get tested too. So do environmental loads, mechanical loads, and electrical loads.

Quality management here follows ISO 9001 and IATF 16949. CMC, Ex, UL, CE, REACH, and RoHS sit on the company certification list as well. Not every product carries the same certification scope. Ask us for the documents that apply to the QS-P202A before you buy.

def urea pump certificate

Qintai sensor factory production line

OEM, ODM and R&D Support for ATEX Pressure transmitter

OEM and ODM services are available from Qintai, covering product design through mass production. Customization follows your specifications, your application and your project needs.

The R&D team handles development and technical support. China Yuchai Power has given Qintai an R&D collaboration award. Qintai supplies Weichai Power, Yuchai Power, and Quanchai Power, and also works with BYD, DINEX, FAWDE, KAMAZ, NAVECO, DEUTZ, SANY, and SINOTRUK. These relationships belong to Qintai's wider sensor business and do not mean those customers use the QS-P202A. Qintai has also exhibited at AAPEX 2024 in Las Vegas, Hannover Messe 2025, and Manufacturing World 2025 in Osaka.

def urea pump Qintai partners

Delivery, Logistics and Packaging

In-stock products that apply to your order ship within one week, subject to stock availability. Production usually takes 1–2 weeks. International orders can move by air freight or sea freight. Express delivery is another option. Warehouse procedures cover standardized storage and inventory management. They also handle product traceability.

Protective foam is one option for packing. So are anti-static materials and reinforced cartons. Customized ATEX Pressure transmitter packaging can be arranged too. Before shipment, the barcode gets checked. Quantity is confirmed and the appearance is inspected. Packaging integrity is also verified.

def urea pump exhibition

package and shipping

FAQ

Q: What industries use hazardous-area pressure transmitters such as this one?

A: Oil and gas, chemical and petrochemical, pharmaceutical, and wastewater treatment processes where flammable gases or vapors may be present.

Q: What does ATEX certification cover?

A: ATEX applies to equipment built for potentially explosive atmospheres. The original scope came under Directive 94/9/EC. Directive 2014/34/EU replaced it. Mine equipment is in scope. Non-mine equipment is too. Mechanical gear counts. So does electrical gear. Dust atmospheres are in scope too. Flammable gases are as well. Vapors and mist are included. Markings for QS-P202A on this page apply to gas atmospheres (G).

Q: Which markings does the QS-P202A carry?

A: The unit carries three ATEX marks. One is ATEX II 2G IIC T6. Another is ATEX II 1G IIC T6. The third is ATEX II 3G IIA T3.

Q: Do I need an isolation barrier?

A: Intrinsically safe transmitters must be used with an intrinsically safe isolation barrier to achieve intrinsic safety. Please confirm the protection method of the QS-P202A with our team.

Q: How fast can you deliver?

A: Applicable in-stock products ship within one week. Typical production takes 1–2 weeks.

Q: Can you customize the product?

A: Yes. OEM and ODM services go from design to mass production. Packaging is customizable.

Q: How can I choose the right model?

A: Tell us the medium, the zone classification, and the pressure range. Our team will then help you pick This product that fits.

Contact Us

Send your medium, zone classification, and pressure range for the ATEX Pressure transmitter to info@qt-sensor.com. Our engineers will confirm available options for the QS-P202A, including the applicable ATEX marking.

Online Message

Our customers’ satisfaction speaks for our quality — contact us to experience the same reliable service.