ultrasonic liquid level transmitter

QS-P415
Measurement range from 0.5m to 500m H2O
 Easy to install, immersion type measurement
 Various signal output for industrial standard
 High accuracy, good stability
 Intrinsically safe explosion-proof
Product Description

Ultrasonic Liquid Level Transmitter Guide and QS-P415 Immersion Level Transmitter

Start with three things: your tank, the liquid inside it, and the conditions on site. On this page you will see how an ultrasonic liquid level transmitter takes readings without touching the liquid. You will also see how it stacks up against the QS-P415 immersion level transmitter made by Xi'an Qintai Automotive Emission Technology Co., Ltd. Qintai has been making sensors since 2001. The QS-P415 comes listed with a 0.5 m to 500 m H2O measuring range and an intrinsically safe design. Compare the two, look over the specs, then send us the details of your tank. We will help you narrow down the pick.

QS-P415 ultrasonic liquid level transmitter Key Features

The QS-P415 is an immersion type transmitter. You place it in the liquid, and its range is stated in meters of H2O.

  • Measurement range: 0.5 m to 500 m H2O
  • Installation method: immersion in the liquid
  • Output: various industrial standard signals
  • Explosion protection: intrinsically safe design
  • Performance: described by the manufacturer as high accuracy and good stability, with no accuracy figure listed in the available data

Product Specifications

ItemDetails
ModelQS-P415
Measurement range0.5 m to 500 m H2O
Measurement typeImmersion
OutputVarious industrial standard signals
PerformanceHigh accuracy, good stability
Explosion protectionIntrinsically safe

Accuracy is not in the data we have. Neither is the exact output signal type, the supply voltage, the process connection, the materials, the operating temperature, the ingress protection, or the certificate details for the intrinsically safe design. We did not guess at any of these. Check them with us first, before you place an order.

How Ultrasonic Level Measurement Works

This product does its job without ever touching the liquid. High-frequency sound pulses go out from the unit toward the surface. The echo that bounces back gets picked up by a transducer. Distance then comes from the time of flight.

The liquid stays clear of every part of the sensor. Corrosive media therefore suit this method well. Wear and upkeep that come with mechanical float switches are gone too. Manual checks in spots that are hard to reach can stop as well. Specs change between models: range, resolution, outputs, ingress protection and hazardous-area approvals. For the exact unit you mean to buy, read the datasheet. Values for ultrasonic units on this page do not cover the QS-P415.

Immersion or Ultrasonic: Which Fits Your Tank?

Some tanks call for measurement with no contact, corrosive or hygiene-sensitive ones for example. Here This product is the right tool.

Looking for an immersion unit that sits right in the liquid? Range on the QS-P415 is listed up to 500 m H2O. Foam and steam weaken sound signals. Tanks like those are often a better fit for an immersion unit. Most of the time, ultrasonic sensors work best at atmospheric pressure. If high pressure or vacuum is in play, another sensor type might do the job.

Applications

Below are the jobs an ultrasonic liquid level transmitter usually takes on:

  • Chemical and petrochemical tanks and reactors, where the aim is to help prevent overflows
  • Water tanks. Wastewater tanks. Reservoirs count. Water towers too. Channels as well. This keeps overflows and dry pump runs from happening.
  • Oil tanks in energy plants. Boilers count too. Cooling towers as well.
  • Food and beverage tanks, along with pharmaceutical ones, where the medium must not touch the sensor
  • Solids level in cement and mining silos and hoppers
  • Irrigation ponds and water storage tanks in agriculture

The QS-P415 is meant for immersion level measurement at industrial tank sites, including sites with explosive atmospheres where an intrinsically safe design is required. Confirm suitability for your medium before ordering.

def urea pump warehouse

Installation Precautions

Before you install This product, go through this list:

  • Pipes should not block the sound path. Brackets should stay clear. Agitators need to stay clear too.
  • When the sensor sits too close to the tank wall, you can get false echoes. Leave some space there.
  • Point the sensor straight down at the liquid surface when you fit it.
  • Do not use thick foam or steam that runs hot.
  • The temperature should stay inside the rated range.
  • Keep clear of large motors and high-voltage lines. Where that is not possible, add shielding.

Buying the QS-P415? Send us your tank depth and the output you need before you order. That way we can check the fit.

Company Background, Testing and Quality

Xi'an Qintai Automotive Emission Technology Co., Ltd. has 420 employees. Of those, 86 work as R&D technicians. The company is a national high-tech enterprise. Its testing center covers 400 m² and runs more than 100 testing and inspection devices. Checks there go from microscopic inspection and dimensional measurement to physical and chemical properties. Environmental loads get tested, and so do mechanical and electrical ones.

Quality management follows ISO 9001 and IATF 16949. At company level, the certifications cover CMC, Ex, UL and CE. REACH and RoHS sit in that same group. Documents for a given model should be confirmed before you order.

def urea pump certificate

Qintai sensor factory production line

OEM and ODM Support

Qintai offers OEM and ODM services. Product design through to mass production is covered. Need changes for your specifications, your application, or your project? Just ask. The in-house R&D team handles technical support. For the QS-P415, check availability with our team first.

def urea pump Qintai partners

Packaging and Delivery

There are a few ways to pack an order. Protective foam is one choice. Anti-static materials are another. Reinforced cartons also get used. Customized packaging is available too. Staff check a few things before shipment. Barcodes are checked. Quantity gets ultrasonic liquid level transmitter checked too. They also look at appearance. Packaging condition gets a check as well.

Qintai states that selected in-stock products ship within one week. Typical production lead time is 1–2 weeks. Air freight, sea freight, and express delivery are available. We confirm the lead time for the QS-P415 once you send your quantity.

def urea pump exhibition

package and shipping

FAQ

Q: What is the measurement range of the QS-P415?

A: The range runs from 0.5 m to 500 m H2O. This is an immersion type unit. You get several industrial standard signal outputs with it.

Q: Is the QS-P415 an ultrasonic unit?

A: No. It works as an immersion type transmitter. Sound pulses let ultrasonic units measure without any contact.

Q: Does the QS-P415 suit hazardous areas?

A: The design is intrinsically safe. Ex is among the company-level certifications. Certificate details for this model, though, are not listed here. Confirm the documents first if you plan to use it in a hazardous area.

Q: Can I request customization?

A: Yes. OEM and ODM work is available from Qintai. We build to your specs, your application, and the needs of your project.

Q: What causes unstable ultrasonic readings?

A: Obstacles in the sound path are one usual cause. Others: a sensor mounted too close to the tank wall, foam, steam, a tilted install, and strong electromagnetic fields.

Contact Us

Email your tank depth, the ultrasonic liquid level transmitter signal output you need, the medium, and the quantity to info@qt-sensor.com. We can then compare ultrasonic and immersion options with you.

Online Message

Our customers’ satisfaction speaks for our quality — contact us to experience the same reliable service.